中文版 | English 
Home Company News Products Cases Service Feedback Contact
 
 
  Product Categories
  · The desulfurization circulating p...
  · The desulfurization circulating p...
  · What ZJ had series slurry pump
  · ZJL series liquid slurry pump
  · The HS modification (AH) series s...
  · (R) VS liquid slurry pump under m...
  · ZGB model series slurry pump
  · TS (TSH) series gravel pump
  · WN series dredging pump
  · TL (R) series desulphurization pu...
  · AF series foam pump
  · SX series double suction pump
 
  Contact Us
Tel:0311-67266522
Fax:0311-67693296
Phone:15511361821
E-mail:Sjzzs_heb@126.com
2190346654@qq.com
Manager:yongli zhang . The managerang
Online Service
欢迎用QQ联系我们! 欢迎用MSN与我联系!
 
News Current Location:  Home >> News  【 Return 】  
Installation of mechanical seal for slurry pump
Author:Shijiazhuang Zurish Industry Pump Co., Ltd  Time:2018-06-23 08:56:47  Visits:963  
. Check whether the type and specification of mechanical seal of slurry pump installed is correct.
. Check whether the dimension precision, geometric precision and interrelationship between slurry pump and mechanical seal installation are in accordance with the technical requirements. There are mainly the following aspects:
1. Radial run-out tolerance of the shaft (or sleeve) installed in the mechanical sealing part, surface smoothness of the shaft (or sleeve) and tolerance of outer diameter.  
2. Vertical tolerance of the sealing chamber and gland to the center line of the axis (or sleeve) at the locating end.  
3. Install the end part of the shaft (or sleeve) of the moving ring seal ring, and install the chamfer Angle and finish of the end part of the shell hole of the mechanical seal.  
4. Axial displacement of rotating shaft under mechanical seal when working.  
. During the installation of mechanical seal, it shall be kept clean and shall not be allowed to strike the sealing element with tools to prevent damage and damage.  
.When installing, the surface of the moving and static rings shall be coated with a layer of clean machine oil and turbine oil. The auxiliary sealing ring (including moving ring seal ring and static ring seal ring) shall also be coated with clean machine oil or turbine oil before installation to ensure smooth installation.  
, the static ring seal trap after static ring back, in sealed inside the end cover, should pay attention to not hurt the static ring end face, to ensure the static ring end face perpendicular to the center line of the end cover, and pay attention to the static ring back anti-rotating slot to stop pin, but can't contact.  
The rotating part of the mechanical seal shall be fixed by two fixing screws and shafts on the spring seat. When tightening the fixing screws, the working length of the spring shall be ensured.
 
 
All Rights Reserved:Shijiazhuang Zunsheng Pump Co.,Ltd (C) Http://www.sjzzunsheng.com
Tel:0311-67266522    Fax:0311-67693296    E_Mail:Sjzzs_heb@126.com
Add:Changan district of shijiazhuang in hebei province Tangu east city gold Ruicheng C2-1-1902    冀ICP备13018851号-1    By:Sjznet.net